Westburne is much more than an electrical supplier. If you want to program the larger micrologix, you'll need rslogix micro starter. Li qi and shu an introduction to science and civilization in china.
#RSLOGIX 500 EMULATOR MANUAL MANUAL PDF#
U:\Engineering\AB_PLC_Procedure2.Download RSLOGIX MICRO STARTER LITE MANUAL PDF Step 16: You can minimize RSLinx but DO NOT close it since RSLogix500 requires RSLinx running for upload/download or going online. You must correct the problem and clear the X before going to the next step.
#RSLOGIX 500 EMULATOR MANUAL DRIVER#
Please verify that you are using the correct cable (1747-PIC) and the cable is securely plugged into the RS- 232 port of your computer and the DH485, RJ45 phone jack port of the SLC-500 processor and the communication driver is correct. U:\Engineering\AB_PLC_Procedure2.doc 11 of 16ġ2 If you see an X on top of the processor icon, (as shown below), that indicates that the computer is not communicating with the processor. Click on the AB_PIC, DH485 driver and you should see your computer and the SLC500 icon as shown below. U:\Engineering\AB_PLC_Procedure2.doc 10 of 16ġ1 Step 14: After successfully configuring your COM port to use the PIC driver, you should see the following screen (make sure under Status, it says Running) Step 15: You can close the above window by pressing Close button. Step 13: Make sure you have the cable (1747-PIC) plugged into the front of the SLC500 (DH485, RJ45 phone jack port) and plugged into your computer. U:\Engineering\AB_PLC_Procedure2.doc 9 of 16ġ0 1747-PIC / AIC+ Driver Step 12: If 1747-PIC / AIC+ driver is selected. Step 11: You can minimize RSLinx but DO NOT close it since RSLogix500 requires Rslinx running for upload/download or going online. Please verify that you are using the correct cable (1747-CP3) and the cable is securely plugged into the RS- 232 port of your computer and the RS-232 port of the SLC-500 processor and the communication driver is correct. U:\Engineering\AB_PLC_Procedure2.doc 8 of 16ĩ If you see an X on top of the processor icon, (as shown below), that indicates that the computer is not communicating with the processor. Click on the AB_DF1, DH485 driver and you should see your computer and the SLC500 icon as shown below.
Step 9: After successfully configuring your COM port to use the DF1 driver, you should see the following screen (make sure under Status, it says Running) Step 10: You can close the above window by pressing Close button. If you see any error, please verify that you are using the correct cable and the cable is securely plugged into the RS-232 port of your computer and the SLC-500 processor.
#RSLOGIX 500 EMULATOR MANUAL DRIVERS#
Skip this step if RSWho is open (see step 2) Step 4: Select Communication Configure Drivers U:\Engineering\AB_PLC_Procedure2.doc 4 of 16Ĩ Step 8: The device window should show SLC-CH0/Micro/PanelView and the Auto Configuration was successful.
U:\Engineering\AB_PLC_Procedure2.doc 3 of 16Ĥ Step 3: If RSWho is not open as shown below, Select Communication RSWho to open it. This screen shows that RSWho is open and DH-485 (PIC box) communication driver is currently being used.
This screen shows that RSWho is open and RS232 DF1 communication driver is currently being used. Go to step 3 if RSWho is not already open. U:\Engineering\AB_PLC_Procedure2.doc 2 of 16ģ Step 2: This screen shows that RSWho is open and no communication driver is currently being used. Simply hit OK, and then close any program that might be using the COM port to continue.
If you receive either of the following error messages when starting RSLinx, it means that you have some other program running that currently has control of the COM port (usually COM1).
#RSLOGIX 500 EMULATOR MANUAL SERIAL#
Make sure the computer cable is NOT plugged into the front of the SLC500 (RS232 port serial cable or DH-485 port if a PIC cable is being used). 1 Allen Bradley PLC connection procedure (RSLogix 500 Version 3.1.9, RSLinx Version 2.1) Step 1 5: RSLinx start up procedure (Sheet 2 to 6) Step 6 11: RSLinx setup for RS-232 DF1 driver (SLC 5/03, 5/04 PLC s using the 1747-CP3 serial cable) (Sheet 7 to 9) Step 12 16: RSLinx setup for DH485 driver (SLC 5/01, 5/02, 5/03 PLC s using the 1747-PIC box) (Sheet 10 to 12) Step 17 19: RSLogix 500 start up procedure (Sheet 13 to 16) SLC5/03 SLC5/04 DH485 RS232 DH+ RS232 U:\Engineering\AB_PLC_Procedure2.doc 1 of 16Ģ RSLinx Setup procedure Step 1: Start RSLinx Version 2.1 using the Microsoft Window Start button Note: Always start RSLinx first.